ROHDE & SCHWARZ ZVA8.10 CALIBRATION and ROHDE & SCHWARZ ZVA8.10 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ ZVA8.10 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ROHDE & SCHWARZ ZVA8.10 (1145.1110.10)   Description / Specification:   Spec Sheet 
ROHDE & SCHWARZ ZVA8.10 8 GHz Vector Network Analyzer, 4 Port, 50 Ohm

The R&S ZVA8 (1145.1110.10) 8 GHz Vector Network Analyzer is an ideal choice for measurements on active and passive components and modules, which require high performance and wide versatility. It instruments support scalar and vector measurements on mixers and converters (linear and nonlinear) and noise measurements on amplifiers as well as pulsed measurements for aerospace and defense applications. Specifications. Number of test ports: 4. Frequency range: 300 kHz to 8 GHz. Frequency resolution: 1 Hz. Number of measurement points: 1 to 60001 (user-selectable). Measurement bandwidths: 1/2/5 steps, 1 Hz to 1 MHz. Measurement time per test point: < 3.5 µs (CW mode, 1 MHz measurement bandwidth). Switching time Between channels with no more than 2001 points: < 1 ms. Max. dynamic range at (100 MHz to 4 GHz): 130 dB, typ. > 140 dB. Max. Output power at test port (50 MHz to 4 GHz): –40 dBm to +13 dBm, typ. –45 dBm to +15 dBm. Impedance: 50 ohm. Test ports: type N, female. Options. ZVA8-B16 (1164.0209.10), Direct Generator/Receiver Access. ZVA8-B21 (1164.0009.02), Generator Step Attenuator Port 1. ZVA8-B22 (1164.0015.02), Generator Step Attenuator Port 2. ZVA8-B23 (1164.0021.02), Generator Step Attenuator Port 3. ZVA8-B24 (1164.0038.02), Generator Step Attenuator Port 4. ZVA8-B31 (1164.0044.02), Receiver Step Attenuator Port 1. ZVA8-B32 (1164.0050.02), Receiver Step Attenuator Port 2. ZVA8-B33 (1164.0067.02), Receiver Step Attenuator Port 3. ZVA8-B34 (1164.0073.02), Receiver Step Attenuator Port 4. ZVAB-B4 (1164.1757.02), Oven Quartz (OCXO). ZVAB-B14 (1305.6306.02), Universal Control Interface I/O Port. ZVAB-K2 (1164.1657.02), Time Domain. ZVA-K4 (1164.1863.02), Frequency Conversion. ZVA-K5 (1311.3128.02), Mixer Phase Measurement. ZVA-K6 (1164.1540.02), True Differential Mode. ZVA-K7 (1164.1511.02), Pulsed Measurements. ZVA-B7 (1164.1492.03), Pulsed Measurements with increased recording time. ZVA-K8 (1307.7022.02), Converter Control Software. ZVA-K9 (1311.3128.02), Mixer Delay without LO Access. ZVA-K17 (1164.1070.02), 5 MHz Receiver Bandwidth. ZVA-K27 (1164.1892.02), Internal Pulse Generators. ZVA-K30 (1164.1828.02), Noise Figure Measurements.



 

Standard Calibration $540.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ ZVA8.10. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your ROHDE & SCHWARZ ZVA8.10 CALIBRATION and/or ROHDE & SCHWARZ ZVA8.10 8 GHz Vector Network Analyzer, 4 Port, 50 Ohm REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: